@article{Koryahin_Mykytyuk_Turchyn_Blavt_Prystynskyi_Stadnyk_2021, title={Integration of Information Systems in the Control of Heart Rate in the Process of Physical Education}, volume={21}, url={https://tmfv.com.ua/journal/article/view/1412}, DOI={10.17309/tmfv.2021.1.01}, abstractNote={<p><strong>The study objective.</strong> Substantiation and implementation of the heart rate monitoring tool, developed on the basis of information systems for the rapid registration of cardiac rhythm during exercise.<span class="Apple-converted-space"> </span></p> <p><strong>Material and Methods. </strong>The study was implemented at the theoretical and empirical level. The basis of the study is the use of a set of theoretical methods: scientific analysis and synthesis, comparison, systematization, induction and deduction, generalization. The following methods of empirical research were used: description, empirical comparison, technical modeling, sphygmographic method of registration of pulsograms.<span class="Apple-converted-space"> </span></p> <p><strong>Results. </strong>According to the results of the search activity, a device designed to monitor heart rate in real time was presented. To implement the new electronic method and heart rate monitor of the functional state of the cardiovascular system, an optical block that eliminates the subjective determination of control results associated with the probability of errors was created. The use of an optical unit provides a fast dynamic picture of heart rate measurement, since the unit uses an optical sensor. Spectral characteristics of blood, which change under the influence of physical activity, were used for heart rate registration. Positive characteristics that ensure the quality of real-time HR monitoring procedures using the developed device in addition to high technical parameters are: high level of sensitivity, wide dynamic range, harmonized frequency response, linearity of conversion, note also non-invasiveness, security in application, low energy consumption signal, and transformations that do not affect or distort the control results.<span class="Apple-converted-space"> </span></p> <p><strong>Conclusions. </strong>The use of information systems in heart rate control ensures the accuracy of the measurement information and the correspondence between the degree of scientific reliability and practical value of the obtained results.</p>}, number={1}, journal={Physical Education Theory and Methodology}, author={Koryahin, Victor and Mykytyuk, Zinoviy and Turchyn, Yaryna and Blavt, Oksana and Prystynskyi, Volodymyr and Stadnyk, Volodymyr}, year={2021}, month={Mar.}, pages={5–11} }